Extraction Snorkles & Hot Wire Cutters
There are 4 Extraction Snorkel stations located in the Project Assembly Space G1.21. These snorkels must be used when operating the hot wire cutters or soldering.
The extraction workstations should not be used for
painting (spray booth must be used)
casting (all casting can be undertaken in the HOT or WaM workshops)
or
any processes with highly volatile substances
If you are unsure, ask a dFab staff member
Extraction Snorkel Operation
To operate the extraction snorkels,
Change the exhaust fan switch to the ON position. Once the extraction is in operation a Green LED indicator light will illuminate.
If this light does not illuminate, contact dFab staff.
Open extraction gate
Position hood 15-20cm from the work area
To terminate extraction, change the exhaust fan switch to the OFF position. This will turn off the LED indicator light.
Hot Wire Cutter Operation
Turn on Extraction & ensure the extraction gate is open
Plug in hot wire cutter & turn socket switch on
Turn hot wire cutter switch ON
Test cut a piece of foam.
If the foam does not cut cleanly, adjust the dial to modify the hot wire temperature
Cut all desired pieces of foam
Turn hot wire cutter switch OFF
Turn socket switch OFF & Unplug the hot wire cutter from the wall socket
Turn off Extraction
Never touch the tensioned wire with your hands or any other body part
Severe burns can occur with inappropriate use.
Much care must be taken whilst operating the foam cutters.
Last updated